CriticalOpen

Immediate shutdown of affected equipment, isolate leak, deploy spill containment, and assign maintenance technician to repair hydraulic line and inspect for further damage.

Due not setCreated May 17, 2026, 10:24 PMUpdated May 17, 2026, 10:24 PMTwin Screw Extruder - MEGA 50

Complete Task

Record the actual work performed before closing the task.

Edit Task

Human review can correct the machine, priority, status, due date, action, and notes.

Original Request

One-time issue that generated this corrective task.

Hydraulic leak near injection unit. Oil is dripping under the extruder and operators report pressure fluctuation.

Production stopped: YesSafety concern: YesQuality affected: YesSubmitted May 17, 2026, 10:24 PM
Issue Type
Hydraulic system leak at injection unit
Production
Production stopped due to hydraulic failure and pressure fluctuation.
Safety
High—oil spill and potential for slips or equipment damage, risk of hydraulic system failure.
Quality
High—pressure fluctuation leading to defective parts.

Completion Log

Human completion record for this one-time task.

No completion logs recorded yet.

Machine Maintenance History

Other maintenance tasks on this machine for context around this one-time issue.

CriticalRequest-based

Steer 50 was shut down due to a vacuum pump overheating error.

Record technician assigned, inspection result, root cause, parts replaced, downtime, and final operating condition. Confirm line restart time and production impact before closing. Manager review recommended before marking complete.

OpenDue 2026-05-27Created May 27, 2026, 7:04 PM
CriticalRule-based

Extruder: Never operate without installation of a protection device against the

This prevents catastrophic failure or risk to personnel from overpressure events. Periodically verify the device is installed and functional.

OpenDue not setCreated May 23, 2026, 1:47 AM
LowRequest-based

No maintenance issue described.

Cancelled during human review because this item should not be treated as active maintenance work.

CancelledDue not setCreated May 19, 2026, 6:49 PM
LowRequest-based

This is a test email. No maintenance issue described.

Cancelled during human review because this item should not be treated as active maintenance work.

CancelledDue not setCreated May 19, 2026, 6:49 PM
HighRequest-based

Pelletizer cutters on the Steer Mega 50 may not be sharp enough, affecting th...

Schedule immediate inspection and sharpening or replacement of pelletizer cutters to prevent further quality deviation. Parts replaced: cutters Notes: The cutters can be resharpened upon the operator's request.

CompletedDue 2026-05-25Created May 19, 2026, 6:48 PM
HighRule-based

Extruder: Never operate without installation of a protection device against the

Never operate without installation of a protection device against the melt pressure rising above the maximum level. Schedule: triggered by condition-based. Notes: This prevents catastrophic failure or risk to personnel from overpressure events. Periodically verify the device is installed and functional.

CompletedDue 2026-05-22Created May 18, 2026, 8:21 PM
CriticalRule-based

Extruder: Never operate without installation of a protection device against the

This prevents catastrophic failure or risk to personnel from overpressure events. Periodically verify the device is installed and functional.

Pending ReviewDue not setCreated May 18, 2026, 8:21 PM
CriticalRequest-based

Hydraulic oil is leaking under the extruder. Operators noticed pressure fluct...

Inspect immediately and stop operation until the issue is assessed.

OpenDue not setCreated May 17, 2026, 10:15 PM
CriticalRequest-based

Hydraulic leak near injection unit. Oil is dripping under the extruder and op...

Inspect immediately and stop operation until the issue is assessed.

OpenDue not setCreated May 17, 2026, 10:10 PM
CriticalRequest-based

Hydraulic leak near injection unit

Inspect immediately and stop operation until the issue is assessed.

OpenDue not setCreated May 17, 2026, 9:39 PM